Description

The Shield T1 range of UPSs is the perfect choice for smaller mission
critical equipment and sensitive devices. The online double conversion
systems gives you clean, continuous, pure sine wave output power.
Available in a range of sizes for various applications.
The T1 UPSs adopts the advanced 3-level technology to achieve high efficiency. The
6 and 10KVA models have a unity output power factor to give you more real power
per KVA. The Shield T1 6-20KVA UPSs have a small foot print and can carry additional
battery banks for longer run times.
The 6,10KVA UPSs are engineered with unity
output power factor and the 1, 2, 3, 15, 20KVA
with 0.9 output power factor hence giving you
more real power.
UPSs come with internal batteries for
standard runtime.
Add external battery banks for longer run
times.
LED and LCD displays on the T1 UPSs for
monitoring status of the UPS and quality or
usage of power.
Optional network card allows for remote
monitoring and access to full UPS diagnosis
and settings.
Full Protection of overvoltage, short circuit
and over temperature.
Automatic fan speed adjustment.
Easy parallel the T1 UPSs for redundancy or
capacity.
Intelligent charge management for long
battery life.
Shield T1
System model
System capacity (KVA)
Input voltage
Phase
Input frequency range
Input PF
Output voltage
Output frequency
Output THDu
Output PF
Overload capability
(Inverter mode)
Efficiency
Display
Option
Interface
Operation temperature
Relative humidity
Storage temperature
W*D*H (mm) with batteries
Weight (kg)
Specification sheet
110VAC-288VAC
Single phase in : Single phase out
40Hz~70Hz
>0.97
50/60Hz
≤2%(linear) ; ≤5% (non-linear)
LED + LCD
USB, SNMP, Dry contacts
RS232,SNMP
0 ~ 40 ℃
0 ~ 95% Non Condensing
-20 ~70 ℃
Mains
Output
Battery
System
Environment
Physical data
©. All Rights Reserved Publication No. SH1PB66. Specifications are subject to change
without notice. While every precaution has been taken to ensure accuracy and completeness herein, Shield assumes no responsibility, and disclaims all liability, for
damages resulting from use of this information or for any errors or omissions.
Voltage regulation ±1%
>0.99
100% load@>176VAC; 80% load@>160VAC
80% load@>140VAC; 50% load@>110VAC
220V/230V/240V
110%: for 10 min; 125%: for 1min;
150%: for 30 sec (shut down bypass after 1 min)
Overload capability
(Battery mode)
110%: shut down after 1 min; 125%:shut down after 10 sec;
>125%: shut down after 1 sec
Crest factor 3:1
T11Xi T12Xi T13Xi T16Ui T110Ui T115Xi T120Xi
1 2 3 6 10 15 20
>0.98
0.9 1.0 0.9
≤1%(linear) ; ≤5% (non-linear)
87% 91% 90% 95% 93.5%
Battery Voltage (VDC) 36 72 96 192
144*353*222 190*374*336 190*427*336 190*426*705 190*485*705 250*562*650 250*562*710
10.5 21 24.5 56 60 27 34