Shield R11Xi Smart 1KVA/0.9KW smart online double conversion Rack UPS

In stock

Smart 1KVA/0.9KW smart online double conversion tower UPS with LCD/LED display. Wide input voltage. 0.9 power factor. Optional network card.

SKU: R11Xi Category:

The Shield R1 range of UPSs is the perfect solution for flexible rack or
tower mount applications. Used in small to medium data centers
worldwide, the Shield R1 UPSs are designed for longevity and easy
deployment.
With the option of adding up to 8 external battery banks, the Shield R1 takes care of
needs for both short and longer run times. The 6 and 10KVA UPSs are engineered to
give out a unity power factor hence supporting more load per KVA. The Shield R1
UPSs come with intelligent charge management hence improving battery life.
1-3KVA UPSs are engineered with 0.9 output
power factor and 6-10KVA UPSs with unity
output power factor, hence giving you more
real power.
Add up to 8 external battery banks for longer
run times.
LED and LCD displays on the R1 UPSs for
monitoring status of the UPS and quality or
usage of power.
C13 and C19 output ports available on all
UPSs, hard wired output available for 6-10KVA
UPSs.
Optional network card allows for remote
monitoring and access to full UPS diagnosis
and settings.
Flexible configuration – set it up as a rack
mounts UPS or use it as a tower UPS with
provided mounting.
Full Protection of overvoltage, short circuit
and over temperature.
Automatic fan speed adjustment.
Easy parallel the 6,10KVA R1 for redundancy
or twice the capacity.
Shield R1
System model
System capacity
Input voltage
Input frequency
Input frequency range
Input PF
Output voltage
Output frequency
Output THDu
Output PF
Overload capability
(Inverter mode)
Voltage
Efficiency
Display
Option
Interface
Operation temperature
Relative humidity
Storage temperature
W*D*H (mm) with batteries
Weight (kg) with batteries
W*D*H (mm) without batteries
Specification sheet
110VAC-288VAC
40-70Hz
40Hz~70Hz
>0.97
50/60Hz
THD<1% (linear load ), THD<5.5% (non-linear load)
1
>95.5%
LED + LCD
USB, SNMP, Dry contacts
RS232,SNMP
0 ~ 40 ℃
0 ~ 95% Non Condensing
-20 ~70 ℃
Mains
Output
Battery
System
Environment
Physical data
© 2017 Shield. Shield logo is a trademarked property of their respective owners. All Rights Reserved Publication No. SH1PB66. Specifications are subject to change
without notice. While every precaution has been taken to ensure accuracy and completeness herein, Shield assumes no responsibility, and disclaims all liability, for
damages resulting from use of this information or for any errors or omissions.
R11Xi
1KVA/0.9KW
Voltage regulation 1%
11.5 25 31 59
R12X
2KVA/1.8KW
R13X
3KVA/2.7KW
R16U
6KVA/6KW
R110U
10KVA/10KW
>0.99
100% load@>176VAC; 80% load@>154VAC
70% load@>132VAC; 50% load@>110VAC
100% load@>176VAC; 90% load@>160VAC
80% load@>140VAC; 60% load@>110VAC
220V/230V/240V
0.9 1
105%-130%: to bypass 1 min;
150%: to bypass after 30 sec
110%:for 10 min ;125%:for 1min ;
150%:for 30 sec
Overload capability
(Battery mode)
105%-130%: shutdown after 10 sec;
150%: shutdown after 5 sec
110%: shut down after 1 min;
130%:shut down after 10 sec;
>130%: shut down after 200 ms
Crest factor 3:1
87% 91% 90% 95%
36VDC 72VDC >95.5% 96VDC 192VD

 

 

 